Basic Setup

Fitter Constructor

The Fitter constructor accepts keyword arguments for source properties, model selection, physics options, and numerical parameters:

fitter = Fitter(
    # Source properties
    z=1.58,                   # Redshift
    lumi_dist=3.364e28,       # Luminosity distance [cm]

    # Model selection (see sections below for all options)
    jet="powerlaw",           # Jet structure type
    medium="wind",            # Ambient medium type

    # Physics options
    rvs_shock=True,           # Include reverse shock
    fwd_ssc=True,             # Forward shock inverse Compton
    rvs_ssc=False,            # Reverse shock inverse Compton
    kn=True,                  # Klein-Nishina corrections
    magnetar=True,            # Magnetar energy injection

    # Numerical parameters
    rtol=1e-5,                # Numerical tolerance
    resolution=(0.1, 0.25, 10),   # Grid resolution (phi, theta, t)
)

Setting up Data and the Fitter

The Fitter class handles both model configuration and observational data. Add light curves, spectra, and broadband flux directly to the fitter:

import numpy as np
import pandas as pd
from VegasAfterglow import Fitter, ParamDef, Scale

# Create the fitter with model configuration
fitter = Fitter(
    z=1.58,
    lumi_dist=3.364e28,
    jet="tophat",
    medium="ism",
)

# Method 1: Add data directly
t_data = [1e3, 2e3, 5e3, 1e4, 2e4]  # Time in seconds
flux_data = [1e-26, 8e-27, 5e-27, 3e-27, 2e-27]  # erg/cm²/s/Hz
flux_err = [1e-28, 8e-28, 5e-28, 3e-28, 2e-28]   # Error bars

# Add light curve at R-band frequency
fitter.add_flux_density(nu=4.84e14, t=t_data,
                        f_nu=flux_data, err=flux_err)  # All quantities in CGS units

# Optional: Add weights for systematic uncertainties, normalization handled internally
weights = np.ones_like(t_data)  # Equal weights
fitter.add_flux_density(nu=2.4e17, t=t_data,
                        f_nu=flux_data, err=flux_err,
                        weights=weights)  # All quantities in CGS units

# Method 2: Add frequency-integrated light curve (broadband flux)
# For instruments with wide energy bands (e.g., Swift XRT, Fermi LAT)
from VegasAfterglow.units import band, keV

fitter.add_flux(band=band("XRT"), t=t_data,       # named band
                flux=flux_data, err=flux_err,
                weights=weights)  # flux in erg/cm²/s

# Or specify a custom band as (nu_min, nu_max) tuple
fitter.add_flux(band=(0.3*keV, 10*keV), t=t_data,
                flux=flux_data, err=flux_err)

# Method 3: Load from CSV files
bands = [2.4e17, 4.84e14, 1.4e14]  # X-ray, optical, near-IR
lc_files = ["data/xray.csv", "data/optical.csv", "data/nir.csv"]

for nu, fname in zip(bands, lc_files):
    df = pd.read_csv(fname)
    fitter.add_flux_density(nu=nu, t=df["t"],
                            f_nu=df["Fv_obs"], err=df["Fv_err"])  # All quantities in CGS units

# Add spectra at specific times
spec_times = [1000, 10000]  # seconds
spec_files = ["data/spec_1000s.csv", "data/spec_10000s.csv"]

for t, fname in zip(spec_times, spec_files):
    df = pd.read_csv(fname)
    fitter.add_spectrum(t=t, nu=df["nu"],
                        f_nu=df["Fv_obs"], err=df["Fv_err"])  # All quantities in CGS units

Unit Conversion

All API inputs use CGS base units (seconds, Hz, erg/cm²/s/Hz, cm, radians). The VegasAfterglow.units module provides multiplicative constants for convenient conversion from common astronomical units:

from VegasAfterglow.units import day, GHz, keV, mJy, Mpc, deg

# Fitter setup with natural units
fitter = Fitter(z=1.58, lumi_dist=100*Mpc, jet="tophat", medium="ism")

# Load data in astronomer-friendly units
df = pd.read_csv("data/radio.csv")
fitter.add_flux_density(
    nu=5*GHz,
    t=df["t_days"] * day,
    f_nu=df["flux_mJy"] * mJy,
    err=df["err_mJy"] * mJy,
)

# X-ray band specified in keV (converted to Hz via E=hν)
fitter.add_flux_density(
    nu=1*keV,
    t=df_xray["t_days"] * day,
    f_nu=df_xray["flux"] * mJy,
    err=df_xray["err"] * mJy,
)

# Convert model output back to convenient units
result_flux = model.flux_density_grid(times, nus)
flux_in_mJy = result_flux.total / mJy

Available constants: sec, ms, minute, hr, day, yr (time); Hz, kHz, MHz, GHz (frequency); eV, keV, MeV, GeV (photon energy → frequency); Jy, mJy, uJy (flux density); cm, m, km, pc, kpc, Mpc, Gpc (distance); rad, deg, arcmin, arcsec (angle).

Magnitude Conversion

If your data is in magnitudes rather than flux density, use the built-in magnitude converters:

from VegasAfterglow.units import ABmag_to_cgs, Vegamag_to_cgs, filter

# AB magnitudes (e.g., SDSS photometry)
f_nu = ABmag_to_cgs(df["mag_AB"])
f_nu_err = ABmag_to_cgs(df["mag_AB"] - df["mag_err"]) - f_nu  # asymmetric!

# Vega magnitudes with filter name (e.g., Johnson R band)
f_nu = Vegamag_to_cgs(df["mag_R"], "R")

# Get the effective frequency for a filter (for the fitter)
fitter.add_flux_density(nu=filter("R"), t=t_data, f_nu=f_nu, err=f_nu_err)

Supported magnitude systems and filters:

  • Vega magnitudes via Vegamag_to_cgs(mag, filter_name): Johnson-Cousins (U, B, V, R, I), 2MASS (J, H, Ks), Swift UVOT (v, b, u, uvw1, uvm2, uvw2), SDSS (g, r, i, z)

  • AB magnitudes via ABmag_to_cgs(mag): universal zero-point, works for any filter without specifying a name

  • ST magnitudes via STmag_to_cgs(mag, filter_name): HST WFC3/UVIS (F225WF850LP), WFC3/IR (F105WF160W)

The filter() function returns the effective frequency [Hz] for any supported filter name, including survey filters (VT_B, VT_R, w) that only support AB magnitude conversion.

Data Selection and Optimization

Smart Data Subsampling with logscale_screen

For large datasets or densely sampled observations, using all available data points can lead to computational inefficiency and biased parameter estimation. The logscale_screen utility provides intelligent data subsampling that maintains the essential information content while reducing computational overhead.

from VegasAfterglow import logscale_screen

# Example: Large dense dataset
t_dense = np.logspace(2, 7, 1000)  # 1000 time points
flux_dense = np.random.lognormal(-60, 0.5, 1000)  # Dense flux measurements
flux_err_dense = 0.1 * flux_dense

# Subsample using logarithmic screening
# This selects ~5*5=25 representative points across 5 decades in time
indices = logscale_screen(t_dense, data_density=5)

# Add only the selected subset
fitter.add_flux_density(nu=5e14,
                        t=t_dense[indices],
                        f_nu=flux_dense[indices],
                        err=flux_err_dense[indices])

Why logscale_screen is Important:

  1. Prevents Oversampling Bias: Dense data clusters can dominate the chi-squared calculation, causing the MCMC to over-fit specific frequency bands or time periods.

  2. Computational Efficiency: Reduces the number of model evaluations needed during MCMC sampling, significantly improving performance.

  3. Preserves Information: Unlike uniform thinning, logarithmic sampling maintains representation across all temporal/spectral scales.

  4. Balanced Multi-band Fitting: Ensures each frequency band contributes proportionally to the parameter constraints.

Data Selection Guidelines:

  • Target 10-30 points per frequency band for balanced constraints

  • Avoid >100 points in any single band unless scientifically justified

  • Maintain temporal coverage across all evolutionary phases

  • Weight systematic uncertainties appropriately using the weights parameter

Warning

Common Data Selection Pitfalls:

  • Optical-heavy datasets: Dense optical coverage can bias parameters toward optical-dominant solutions

  • Late-time clustering: Too many late-time points can over-constrain decay slopes at the expense of early physics

  • Single-epoch spectra: Broadband spectra at one time can dominate multi-epoch light curves in chi-squared space

Solution: Use logscale_screen() for manual temporal reduction of over-sampled bands.

Handling Measurement Uncertainties

Error bars strongly influence MCMC fitting. Improperly characterized uncertainties can lead to biased parameter estimates or misleading confidence intervals.

The Problem with Small Error Bars

Data points with very small uncertainties dominate the chi-squared calculation:

\[\chi^2 = \sum_i \frac{(F_{\rm obs,i} - F_{\rm model,i})^2}{\sigma_i^2}\]

A single point with sigma = 0.01 mJy contributes 100x more to chi-squared than a point with sigma = 0.1 mJy. This causes the MCMC to:

  • Heavily weight high-precision data at the expense of other observations

  • Potentially fit noise or systematic effects in the “precise” data

  • Produce artificially tight parameter constraints that don’t reflect true uncertainties

Common Scenarios:

  1. Heterogeneous data quality: X-ray data from different telescopes may have vastly different calibration uncertainties

  2. Underestimated errors: Published error bars sometimes only include statistical uncertainty, missing systematics

  3. Calibration offsets: Different instruments may have 5-20% flux calibration offsets not captured in quoted errors

Solutions:

  1. Add systematic error floors

    For data where quoted errors seem unrealistically small:

    # Add 10% systematic floor to error bars
    systematic_floor = 0.1  # 10% of flux
    err_with_floor = np.sqrt(err**2 + (systematic_floor * flux)**2)
    
    fitter.add_flux_density(nu=nu, t=t, f_nu=flux, err=err_with_floor)
    
  2. Use weights to balance bands

    Down-weight bands with suspiciously small errors:

    # Reduce contribution of high-precision optical data
    optical_weight = 0.5  # Effectively doubles the error contribution
    fitter.add_flux_density(nu=5e14, t=t_optical, f_nu=flux_optical,
                           err=err_optical, weights=optical_weight * np.ones_like(t_optical))
    
  3. Inspect residuals by band

    After fitting, check if residuals are consistent across bands. If one band shows systematic deviations while others don’t, the errors for that band may be mischaracterized.

Tip